![Symmetricom TimeHub 5500 User Manual Download Page 149](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592149.webp)
097-55501-01 Revision M – January 2009
TimeHub 5500 User’s Guide 149
Chapter 4 Testing and Configuring the TimeHub
Establishing a Connection to the TimeHub
Communicating by Serial Port
Two RS-232 ports are available on the TimeHub 5500. Connect a computer with
terminal emulation or TimeHub THC software to one of the ports using a
straight-through serial cable.
Using TimeScan THC
Use the following procedure to log in to the TimeHub 5500 for the first time using
TimeScan THC via a serial connection.
1. Connect one end of the cable to the serial port on the computer or terminal and
the other to the Local connector on the rear panel or the Local connector on the
Management card.
2. Start the TimeHub THC application. A dialog box asks if you want to connect to
Comm Port 1. Click
OK
. The TimeHub TimeScan THC window appears, as
shown in
3. Click
RS-232
in the Communication tab and set the Comm Port field to match
the port connected to the TimeHub.
4. Select the baud rate (default baud rate is 9600), then click the
Connect
check
box. The program connects to the TimeHub.
5. Log in as the “admin” user by selecting
Mode of Operation
,
Advanced Mode
,
or by pressing
F5
. The Advanced Mode pop-up window appears.
6. Select the “admin” user from the User Name drop-down box, type
admin
in the
Password field, and then click
Login
.
7. Click
OK
in the pop-up box that says “Logged in to Advanced Mode.”
Ethernet Ports
Use CAT-5 or equivalent cable to connect. Use a straight-through cable to connect to a hub; use a
cross-over cable to connect to a computer.
7588
Command response port
ASCII TL1 commands or THC GUI
7589
Autonomous messages
ASCII TL1 commands or THC GUI
5001 – 20000
User-assigned internal ports
ASCII TL1 commands or THC GUI
Table 4-3. Communications Port Assignments (Continued)
Port #
Function
Protocol