2-3
PERIODIC MAINTENANCE AND TUNE-UP PROCEDURES
This section describes the service procedures for
each section of Periodic Maintenance.
MAINTENANCE PROCEDURES
For checking specific gravity, use a hydrometer to
determine the charged condition.
BATTERY
Inspect initial 1 000 km and Every 4 000 km
The battery must be removed to check the
electrolyte level and specific gravity.
Remove the right frame cover.
Remove battery
lead at the battery terminal.
Remove battery
lead.
Remove battery from the frame.
Check electrolyte for level and specific gravity.
Add distilled water, as necessary, to keep the
surface of the electrolyte above the LOWER
LEVEL line
but not above the UPPER LEVEL
line
.
09900-28403
Hydrometer
Standard specific
gravity
1.28 at 20
O
C
An S.G. reading of 1.22 (at 20 C ) or under means
that the battery needs recharging off the machine:
take it off and charge it from a recharger.
Charging the battery in place can lead to failure of
the regulator/rectifier.
O
To install the battery, reverse the procedure
described above.
Make sure that the breather pipe is tightly
secured and undamaged, and is routed as
shown in the figure.
WARNING:
When installing the battery lead wires, fix the
lead first and
lead last.
Breather pipe
Battery
1
2
Summary of Contents for EN125-2A
Page 1: ...SERVICE MANUAL 99500H06100 01E EN125 2A...
Page 5: ......
Page 31: ...PERIODIC MAINTENANCE AND TUNE UP PROCEDURES 2 18 7 6 6 8 9 B B A...
Page 88: ...FUEL AND LUBRICATION SYSTEM CONTENTS 4 1 4 2 4 6 4 FUEL COCK CARBURETOR LUBRICATION SYSTEM...
Page 95: ...4 7 FUEL AND LUBRICATION SYSTEM...
Page 161: ...7 9 SERVICING INFORMATION 10 13 11 14 12 15 16 21 18 22 19 17 23 20 24...
Page 162: ...SERVICING INFORMATION 7 10 27 25 28 26 29 30 37 33 31 38 34 35 32 39 36...
Page 163: ...7 11 SERVICING INFORMATION 40 43 41 44 45 46 49 47 48 42...
Page 176: ...EN125HU SUPPLEMENTARY SERVICE MANUAL...
Page 181: ......
Page 203: ......