5-65
Chapter 5: The FastTrak 100 RIAD Card (370DDE)
Your choices are as follows:
Abort: Halts the rebuild process. You may elect to retry at a
later date.
Break ECC on Target Drive: If the error is detected on the
source drive, “Break ECC on Target Drive” means that
FastTrak will copy the bad data sector on to the target drive
to assure that both drives are identical. If the error is de-
tected on the target drive, FastCheck will copy the data
contained in the good sector of the source drive again to the
target drive.
Skip the Error Block: FastTrak100 will log the event error and
continue the rebuild process. Use this setting if you want to
detect the presence of errors, but do not want to fix these
errors at the time. You may then decide what to do about the
error(s) detected.
ECC Error Reported on Synchronize
The following screen will appear if a data error is detected on either
source or target drive during Synchronize if you have set the On Errors
setting to “Interactive” within FastCheck’s Options Window for Sched-
uled Synchronization (see page 5-48) or for Manual Synchronization
under Notification options (see page 5-46).
Summary of Contents for SUPER 370DDE
Page 1: ... SUPER 370DDE SUPER 370SDA USER S MANUAL Revision 1 1 SUPER ...
Page 9: ...Chapter 1 Introduction 1 3 370DDE SECTION ...
Page 10: ...SUPER 370DDE 370SDA User s Manual 1 4 SUPER 370DDE Figure 1 1 SUPER 370DDE Image ...
Page 15: ...Chapter 1 Introduction 1 9 370SDA SECTION ...
Page 16: ...SUPER 370DDE 370SDA User s Manual 1 10 SUPER 370SDA Figure 1 1 SUPER 370SDA Image ...
Page 21: ...Chapter 1 Introduction 1 15 GENERAL SECTION ...
Page 52: ...3 6 SUPER 370DDE 370SDA User s Manual Notes ...
Page 163: ...SUPER 370DDE 370SDA User s Manual A 6 APPENDIX A Notes ...
Page 169: ...SUPER 370DDE 370SDA User s Manual B 6 APPENDIX A NOTES ...
Page 171: ...SUPER 370DDE 370SDA User s Manual C 2 APPENDIX A Notes ...