Chapter 3
Installing the StorEdge S1 Enclosure
47
Connecting the Cables
This section contains instructions for connecting SCSI cables and power cables to the
StorEdge S1 enclosure.
To Prepare the Host System
Before connecting the SCSI cables from the host system to the StorEdge S1 enclosure,
you must prepare the host system.
Note –
If your host system supports hot-swap attaching and detaching of external
SCSI devices, do not power off your system. For example, if your host system is a
Netra ct 400 or 800 server or similar, you should not power off the system. Start the
host system preparation at Step 2.
1. Halt operations and power off your host system.
Refer to your host system documentation for instructions on powering off the
system.
2. Install a host adapter card into your host system, if necessary.
Refer to the documentation that shipped with the adapter card for installation
instructions.
3. Have software documents (on the system CD) available during the installation.
Connecting the SCSI Cables
▼
To Connect the SCSI Cables
If the host system has a VHDCI SCSI connector, you need to use the 0.8-meter
VHDCI/SCSI-3 cable.
1. Verify that the host system has been powered off.
Refer to “To Prepare the Host System” on page 47.
Summary of Contents for StorEdge S1 AC100
Page 8: ...viii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 22: ...xxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 30: ...xxx StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 32: ...xxxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 52: ...16 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 64: ...28 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 92: ...56 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 116: ...80 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 128: ...Index 92 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...