StorEdge S1 AC100 and DC100 Installation and Maintenance Manual • March 2002
▼
To Re-attach the Bezel’s Tethers to the Chassis
1. Position one of the tethers in front of its hole in the chassis and angle it so that
half of its head enters the hole in the chassis.
You may need to push the tether’s head in gently.
2. With one half of the tether’s head inside the hole in the chassis, change the angle
so that you can work the head of the tether completely into its hole.
Again, you might need to push the tether’s head gently home.
3. Repeat Step 1 and Step 2 for the tether at the other end of the bezel.
▼
To Clean the Rear Fan Screens
●
Go to the rear of the system and use a vacuum cleaner to clean all the dust and
debris from the fan screens at the rear of the storage enclosure.
FIGURE 5-13
Cleaning the Rear Fan Screens
Removing and Replacing a Netra st D130
or a StorEdge S1 Storage Enclosure
These instructions are for removing a Netra st D130 or a StorEdge S1 storage
enclosure and replacing it with a StorEdge S1 storage enclosure. Refer to the Netra st
D130 Installation and Maintenance Manual, 806-1489, for detailed information
regarding removing the Netra st D130 storage enclosure.
Note –
If your host system supports hot-swap attaching and detaching of external
SCSI devices, do not power off your system. For example, if your host system is a
Netra ct 400 or 800 or similar server, you should not power off the system. Start the
removal of the server at Step 3.
Vacuum these areas
Summary of Contents for StorEdge S1 AC100
Page 8: ...viii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 22: ...xxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 30: ...xxx StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 32: ...xxxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 52: ...16 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 64: ...28 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 92: ...56 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 116: ...80 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 128: ...Index 92 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...