StorEdge S1 AC100 and DC100 Installation and Maintenance Manual • March 2002
7. Slide the drive out.
8. Determine whether you are going to replace the disk drive or not.
■
If you are going to replace the disk drive, go to “To Replace a Hard Disk Drive”
on page 64.
■
If you are not going to replace the disk drive and you are going to continue using
the system, insert a foam filler in the empty drive slot.
■
If you are not going to replace the disk drive and you are returning a defective
enclosure, leave the drive bays empty.
▼
To Replace a Hard Disk Drive
1. If necessary, refer to the documentation that came with your VERITAS VxVM or
Solstice DiskSuite software for any procedures that you might have to perform
before you can replace the disk drive.
2. Open the locking handle on the disk drive.
Push in the direction of the arrow to release the latch.
3. Slide the replacement disk drive into the vacant slot.
4. Firmly push the drive until the locking handle engages and the drive is flush with
the enclosure front.
5. Close the locking handle fully.
6. Replace the front bezel.
Summary of Contents for StorEdge S1 AC100
Page 8: ...viii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 22: ...xxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 30: ...xxx StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 32: ...xxxii StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 52: ...16 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 64: ...28 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 92: ...56 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 116: ...80 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...
Page 128: ...Index 92 StorEdge S1 AC100 and DC100 Installation and Maintenance Manual March 2002...