512
Name
Data Type
Description
ARRAY of
STRUCT of:
Last tightening data for each of the 4 interfaces. Each array entry corresponds
to an interface.
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Job Sequence
Number
UINT
Sequence number of the running job.
Job Number
USINT
Instance number of job currently running. Ignored if 0.
Parameter
USINT
Number of the parameter that produced the tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
USINT
Number of results performed in the current batch for the parameter.
Batch
USINT
Number of results required for a batch in the parameter.
Total size: 68 bytes
513
Name
Data Type
Description
ARRAY of
STRUCT of:
Last tightening data for each of the 4 interfaces. Each array entry corresponds
to an interface.
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Total size: 44 bytes
Input Connection Points for Current Operation Status
The connection points in this group provide a view of the current operation status.
530
Name
Data Type
Description
ARRAY of
STRUCT of:
Current status for each of the 4 interfaces. Each array entry corresponds to an
interface.
Parameter Number
USINT
Parameter number (0 means parameter not running.)
Job Number
USINT
Job number. (0 means job not running)
Suspend
BOOL
Count
USINT
Number of tightenings performed in the current batch for the parameter.
Batch
USINT
Number of tightenings required for a batch in the parameter.
Status
USINT
Status of parameter
0 – None
1 – Cycle
2 – Batch
3 – Reject
4 – Batch NOK (batch complete with a counted reject)
Total size: 24 bytes
531
Name
Data Type
Description
ARRAY of
STRUCT of:
Current status for each of the 4 interfaces. Each array entry corresponds to an
interface.
Parameter Number
USINT
Parameter number (0 means parameter not running.)
Job Number
USINT
Job number. (0 means job not running)
Suspend
BOOL
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...