This setting controls the minimum amount of time after a batch completion before another
tightening should be accepted. Any additional tightenings performed within this time after a
batch completion will be automatically considered a reject.
Digital Tool Fields
Unit
Default: ft.lb
Values: in.lb, ft.lb, N.m, cm.kg, m.kg
This setting determines the units of the Torque Min and Max, as well as the torque reported with
each tightening.
Torque Min
Default: 10% of tool capacity
Range: 0 to tool capacity
This setting controls the minimum required torque for a valid tightening. This value must be less
than Torque Max.
Torque Max
Default: 99% of tool capacity
Range: 0 to tool capacity
This setting controls the maximum allowed torque for a valid tightening. This value must be
greater than Torque Min.
Green Torque
Default: 10% of tool capacity
Range: Torque Min to Torque Max
This setting controls the torque at which the green light on the tool will become active. This
value allows you to keep the green light on the tool from activating at minimum torque to
encourage the operator to pull to a torque farther up within the allowed range.
Mode
Default: Peak
Values: Peak, Residual
This setting controls the mode the tool uses to determine the torque.
Direction
Default: Positive
Values: Positive, Negative, Both
This setting controls the allowed torque directions for the parameter.
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...