Chapter 3: Configuring the unit
17 August 2016
Not all tools support this setting. Only click tools with code 1.13 or later and holding tools
support this setting. This setting is only sent to a tool during the learn process
Serial printer format
Default: None
Values: None, Line, CSV
This setting determines the format used for serial printing of tightenings.
Bypass Verify Inputs
Default: no
This setting determines if the Verify Tool and Verify Socket inputs are ignored. See the
GIM400 User Manual for more information about the inputs.
Startup Operation
Default: Last
Values: Last, None
This setting determines what operation will be run on unit startup. If set to Last, the last running
operation when the unit turned off will be restarted at the beginning of the operation when the
unit turns on. If set to None, the unit will be in the No active parameter state on startup.
Exacta 1200 Mode
Default: Batch
Values: Batch, Single
This setting determines how the Exacta 1200 will behave when it loses communication with the
Global 400mp. If set to Batch, the Exacta 1200 will record tightenings up to the completion of a
full batch before disabling. If set to Single, the Exacta 1200 will disable after each result until it
receives confirmation that the result was received by the Global 400mp.
Enter new Password
Figure 38: Enter new Password screen
Function keys
1.
REMOVE – Clears the unit password and returns to the Unit Setup screen.
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...