Chapter 3: Configuring the unit
17 August 2016
Autoclear Time
Default: 1
Range: 1 to 255 seconds
This setting controls the amount of time the torque must be steady before it is reported.
Head Length
Default: 36.50 mm
Values: 0 to 100 mm
This setting is used to tell the tool how long the head is for the parameter. The standard head
length is 36.50 mm.
If this value is not entered correctly, torque measurements will be invalid.
Air Tool Fields
Timer Min
Range: 0 to 65.5 s
This setting controls the minimum time the tool must run for a valid tightening.
Timer Max
Range: 0 to 65.5 s
This setting controls the maximum time the tool can run for a valid tightening.
Timer Pulse
Range: 0 to 65.5 s
This setting controls the minimum time a tool needs to pulse, if using a pulse tool algorithm.
Timer Bump
Range: 0 to 65.5 s
This setting controls the maximum time the tool can run without creating a status. This setting is
provided to allow the tool trigger to be bumped without creating a spurious reject.
Timer Clutch
Range: 0 to 65.5 s
This setting controls the minimum time the tool’s trigger must be held after clutching out.
Threshold 1
Range: 0 to 99.9 psi
This setting controls the pressure at which the transducer will start monitoring a tightening.
Threshold 2
Range: 0 to 99.9 psi
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...