Introduction
This chapter describes the support for the ToolsNet Open Protocol in the Global 400mp.
Implementation of the protocol is according to ToolsNet Open Protocol version 3.5.
The Global 400mp reports System Type as 29 and System Name as “Global 400”.
Configuration Options
Figure 51: Main menu - Network
Setup
Figure 52: Network Setup Menu –
ToolsNet
Figure 53: ToolsNet Settings
Enable ToolsNet?
Default: no
This setting determines if the Global 400mp will attempt to establish ToolsNet connections.
Unlike the other network protocols supported by the Global 400mp, ToolsNet requires the
controller to establish connections. Since the Global 400mp will repeatedly make network
requests to attempt to establish network connections to the ToolsNet server, you should only
enable ToolsNet if you have a server set up in the network.
PIM server address
Default: 192.168.1.66
This setting controls the IP address the Global 400mp will use to establish a ToolsNet
connection.
PIM server port
Default: 6575
Range: 0 to 65535
This setting controls the port the Global 400mp will use to establish a ToolsNet connection at the
PIM server address.
PIM retry interval
Default: 60 seconds
Range: 0 to 3600 seconds
This setting controls how long the Global 400mp will wait after a failed attempt to establish a
ToolsNet connection before it tries again.
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...