Chapter 3: Configuring the unit
17 August 2016
Last Calibration
This field is used to store the date when the tool was last calibrated. The display order of this
field is:
year-month-day hour:minute:second
For digital tools, this field is reported by the tool and must be updated in the tool instead of
edited in the Global 400mp.
For other tools, this field must be updated manually when the tool is calibrated and is for
informational purposes only. The date can be set to the current time in the Global 400mp by
selecting
Set Now
at the end of the Last Calibration row and pressing the ENT key.
Next Calibration
This field is used to store the date at which the tool should be recalibrated. The display order of
this field is:
year-month-day hour:minute:second
For digital tools, this field is reported by the tool and must be updated in the tool instead of
edited in the unit.
For other tools, this field must be updated manually when the tool is calibrated. The date can be
set to the current time in the Global 400mp by selecting
Set Now
at the end of the Next
Calibration row and pressing the ENT key. This can be helpful when the recalibration period is a
full month because you will only need to update the month (and year when at the end of the
year).
The tool can be configured via the PC software application to reject all results after this date
passes.
Cycles
This field tracks the total number of cycles performed by the tool since the tool radio was
connected to the Global 400mp. This cycle count is incremented for both accepted and rejected
cycles.
This field cannot be edited. If the radio connected is erased and then is reconnected to a Global
400mp, the cycle count will restart at 0.
Last PM at
This field stores the cycle count at which the tool last received preventative maintenance. This
field must be updated manually when the tool is serviced. The count can be set to the current
cycle count by selecting
Set Now
at the end of the row and pressing the ENT key.
Cycles before PM
Range: 0 to 4,294,967,295
This field indicates the number of cycles between preventative maintenance for the tool. If this
field is set to 0, no tracking of cycle counts for preventative maintenance is performed.
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...