7. Identifier part 3
This command sets the Identifier part 3 (VIN characters 51-75) reported by the unit in tightening
result messages and the ACOP MID 0152 Multiple identifier and result parts notifications.
Data: up to 25 characters
Example:
*%07%GU49CN53%*
8. Identifier part 4
This command sets the Identifier part 4 (VIN characters 76-100) reported by the unit in
tightening result messages and the ACOP MID 0152 Multiple identifier and result parts
notifications.
Data: up to 25 characters
Example:
*%08%RU39CN53%*
10. Reset batch count
This command resets the count of all currently running parameters on the unit.
Data: none
Example:
*%10%%*
11. Start Parameter
This command instructs the unit to start a parameter. Any other running parameter or job will be
stopped before starting the new parameter.
Data: number of up to 3 digits specifying the parameter number to select (1-100)
Example:
*%11%73%*
This bar code would select parameter 73.
13. Stop
This command instructs the unit to stop any running parameter or job.
Data: none
Example:
*%13%%*
30. Reset parameter batch count
This command resets the count of the specified parameter. If the specified parameter is not
running, this bar code is ignored.
Summary of Contents for Global 400mp
Page 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Page 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Page 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Page 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Page 73: ...TEMPLATE GLOBAL 400 ...