Press the
Load measurement
softkey.
The wizard for calibrating the load measure-
ment is started.
–
Follow the instructions on the display.
–
If the message
Calibration
failed
appears, press the softkey.
–
Repeat the process.
After the calibration has been completed suc-
cessfully, the message
Successful cal-
ibration
appears.
–
Switch the truck off and on again.
The calibration is now complete.
NOTE
If the message
A6701
Fault: Monitor-
ing of assistance system
ap-
pears during the calibration, perform the cali-
bration again.
Precision load measurement (var-
iant)
This assistance system is available only if the
truck is equipped with the "load measurement"
variant.
The "Precision load measurement" variant al-
lows the weight of the load being picked up to
be measured and displayed on the display-op-
erating unit accurate to within 1% of the rated
capacity of the truck.
NOTE
If the load is to be measured exclusive of the
load pick-up device, run the tare function. See
the next section.
–
Pick up the load safely.
–
Press the button.
The first menu level appears.
–
Press the "Load" softkey .
Fleet manager
Load measurement
Lift mast tilting
6219_003-278_en
Operation
4
Load-dependant assistance systems
175
56368011531 EN - 01/2021 - 05
Summary of Contents for 6219
Page 2: ......
Page 4: ......
Page 16: ......
Page 17: ...1 Foreword ...
Page 25: ...Foreword 1 Your truck 9 56368011531 EN 01 2021 05 ...
Page 54: ...Foreword 1 Environmental considerations 38 56368011531 EN 01 2021 05 ...
Page 55: ...2 Safety ...
Page 71: ...Safety 2 Residual risk 55 56368011531 EN 01 2021 05 ...
Page 87: ...3 Overviews ...
Page 88: ...Overview Overviews 3 Overview 72 56368011531 EN 01 2021 05 ...
Page 92: ...Shelves 6219_901 015_V3 Overviews 3 Shelves 76 56368011531 EN 01 2021 05 ...
Page 109: ...4 Operation ...
Page 455: ...5 Maintenance ...
Page 497: ...6 Technical data ...
Page 528: ...Technical data 6 Information on the auxiliary hydraulics 512 56368011531 EN 01 2021 05 ...
Page 538: ......
Page 539: ......