362
14 January 2021, SmartScanIS User’s Guide for Union Pacific, EUD-2016026-00 Rev.2
7
Put the heat source in a shady area, out of direct sunlight and out of the wind.
8
Wait about 8 minutes for the heat source to reach operating temperature and stabilize.
The heat source has reached operating temperature and stabilized when the
temperature meter needle remains centered.
Once the temperature stabilizes, calibration may begin. Once stabilized, the
temperature will change less than plus-or-minus one degree Fahrenheit.
9
With the power cord to the front of the scanner, place the calibrated heat source on the
bearing scanner.
10
Plug your computer into COM3.
11
Turn on your computer.
12
Be sure that your computer has installed communications software, that it is set to use
full duplex, and that the baud rate is set to 9,600.
The baud rate of your computer must match the baud rate of the selected serial port
because they are in direct, one-to-one, communication with one another. For example,
the baud rate for COM3 was set to 9600 at the factory. If the customer changed this
baud rate, your computer must be set to the changed value.
13
Using the serial interface, display the Main menu.
Chapter 11 - Serial Interface
tells how to display the Main menu. The Main menu
looks like this.
STC Integrated Detector System, Milepost-0501.2, Track:Single
05/31/2013
9:35
Main Menu
------------------------------------------------
•
•
•
H) Event Log
I) Setup Menu
J) T94 Train Detail
X) Exit Menu
Summary of Contents for SmartScanIS
Page 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Page 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Page 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Page 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Page 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Page 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Page 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...