Keypad
3-27
SR780 Network Signal Analyzer
Control Keys
[Start/Reset]
If the unit is already making measurements, [Start/Reset] resets any averages and starts
the measurement over. If the measurement is paused, [Start/Reset] starts the measurement
over again. The Run/Pause indicator shows ‘Run’ when measurements are in progress.
If the measurement is triggered, [Start/Reset] does not supply a trigger. If the trigger is
manual armed, [Start/Reset] does not arm the trigger.
If the displays don’t update, see the Operating Hints in Chapter 2 for help.
Command: STRT
[Pause/Cont]
If the unit is already making measurements, [Pause/Cont] halts data acquisition. The
measurement is paused where it is and the displays are not updated. The Run/Pause
indicator shows ‘Pause’ when measurements are paused.
If the measurement is paused, [Pause/Cont] resumes the measurement where it was left
off. To start over, press [Start/Reset]. The Run/Pause indicator shows ‘Run’ when
measurements are in progress.
For Exponential FFT averaging, [Pause/Cont] simply resumes data acquisition without
resetting the average. For Linear FFT averaging, [Pause/Cont] will complete the current
average. If the linear average was already complete, [Pause/Cont] has no effect.
For Swept Sine measurements, [Pause/Cont] simply resumes the sweep where it was
paused.
For Octave Analysis measurements, [Pause/Cont] resets the averages before starting
again (same as [Start/Reset]).
Command: PAUS and CONT
[Start Capture]
[Start Capture] starts storing data in the capture buffer.
If the Trigger Mode is Free Run, capture starts immediately. Otherwise, the selected
Trigger Mode and Source will be in effect and the next trigger event will start capture.
While capture is in progress, the displays do not update. The Capture Progress indicator
shows how much of the desired capture length has been completed. If the Capture Mode
is 1-Shot, capture stops when the buffer is full. Press [Stop Capture] to halt capture
before the buffer is full.
If the Capture Mode is Continuous, once capture is started, it continues indefinitely and
fills the capture buffer in a circular fashion. In this case, press [Stop Capture] to halt
capture with the most recently acquired data stored in the buffer.
Summary of Contents for SR780
Page 4: ...ii SR780 Network Signal Analyzer ...
Page 10: ...viii SR780 Network Signal Analyzer ...
Page 18: ...1 2 Getting Started SR780 Network Signal Analyzer ...
Page 39: ...Triggering and the Time Record 1 23 SR780 Network Signal Analyzer ...
Page 40: ...1 24 Triggering and the Time Record SR780 Network Signal Analyzer ...
Page 58: ...1 42 Waterfall Display SR780 Network Signal Analyzer ...
Page 70: ...1 54 Saving and Recalling SR780 Network Signal Analyzer ...
Page 167: ...Status Indicators 3 21 SR780 Network Signal Analyzer ...
Page 188: ...4 6 Menus SR780 Network Signal Analyzer ...
Page 193: ...FFT Frequency Menu 4 11 SR780 Network Signal Analyzer Command FEND d f ...
Page 232: ......
Page 236: ...4 54 Source Menu SR780 Network Signal Analyzer Command STYP i ...
Page 266: ...4 84 Playback Input Menu SR780 Network Signal Analyzer ...
Page 272: ...4 90 Trigger Menu SR780 Network Signal Analyzer ...
Page 288: ...4 106 Swept Sine Average Menu SR780 Network Signal Analyzer ...
Page 326: ...144 Exceedance Statistics Menu SR780 Network Signal Analyzer ...
Page 352: ...4 170 Output Menu SR780 Network Signal Analyzer ...
Page 478: ......