![Stanford Research Systems SR780 Operating Manual And Programming Reference Download Page 408](http://html.mh-extra.com/html/stanford-research-systems/sr780/sr780_operating-manual-and-programming-reference_1359462408.webp)
5-42 Marker
Commands
SR780 Network Signal Analyzer
Marker Commands (Sideband)
SSEP (?) d {, f}
The SSEP command sets (queries) the Sideband Separation for display d. The
parameter f is the sideband separation in Hz.
This command is only valid if the Marker Mode for display d is Sideband.
SDBN (?) d {, i}
The SDBN command sets (queries) the Number of Sidebands for display d. The
parameter i is a number of sidebands from 1 to 50.
This command is only valid if the Marker Mode for display d is Sideband.
HDSP (?) d {, i}
The HDSP command sets (queries) the Harmonic and Sideband Marker Display
for display d.
For Sideband Marker, i=0 selects the Fundamental, i=-1 selects the first lower
sideband, i=1 selects the first upper sideband. The maximum value of i plus or
minus the Number of Sidebands. i<0 is valid only for Sideband marker.
This command is only valid if the Marker Mode for display d is Harmonic or
Sideband.
HRDO (?) d {, i}
The HRDO command sets (queries) the Harmonic and Sideband Marker Readout
for display d. The parameter i selects Absolute (0) or Relative to Fundamental
(1).
This command is only valid if the Marker Mode for display d is Harmonic or
Sideband.
SPWR ? d, i
The SPWR ? command queries the Sideband Power for display d. The parameter
i selects dB Relative to Fundamental (0) or Vrms (1) and is required.
This command is only valid if the Marker Mode for display d is Sideband.
Summary of Contents for SR780
Page 4: ...ii SR780 Network Signal Analyzer ...
Page 10: ...viii SR780 Network Signal Analyzer ...
Page 18: ...1 2 Getting Started SR780 Network Signal Analyzer ...
Page 39: ...Triggering and the Time Record 1 23 SR780 Network Signal Analyzer ...
Page 40: ...1 24 Triggering and the Time Record SR780 Network Signal Analyzer ...
Page 58: ...1 42 Waterfall Display SR780 Network Signal Analyzer ...
Page 70: ...1 54 Saving and Recalling SR780 Network Signal Analyzer ...
Page 167: ...Status Indicators 3 21 SR780 Network Signal Analyzer ...
Page 188: ...4 6 Menus SR780 Network Signal Analyzer ...
Page 193: ...FFT Frequency Menu 4 11 SR780 Network Signal Analyzer Command FEND d f ...
Page 232: ......
Page 236: ...4 54 Source Menu SR780 Network Signal Analyzer Command STYP i ...
Page 266: ...4 84 Playback Input Menu SR780 Network Signal Analyzer ...
Page 272: ...4 90 Trigger Menu SR780 Network Signal Analyzer ...
Page 288: ...4 106 Swept Sine Average Menu SR780 Network Signal Analyzer ...
Page 326: ...144 Exceedance Statistics Menu SR780 Network Signal Analyzer ...
Page 352: ...4 170 Output Menu SR780 Network Signal Analyzer ...
Page 478: ......