9-20
HDW-750/750CE V1
9-17. Crispening Adjustment
Preparation
.
Complete the setting as shown below by using the setup
menu.
MENU : PAINT
PAGE : 07
*
DETAIL1
ITEM :
DETAIL
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot the gray scale chart to fill the entire screen of the
under-scanned picture frame.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
Adjustment point :
1
lens iris
Specifications :
A = 700
±
14 mV.
Adjustment Procedure
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
1.
Complete the adjustment as shown below by using the
setup menu.
MENU :
PAINT
PAGE :
07
*
DETAIL1
ITEM :
CRISPENING
Specifications : Adjust the crispening level such that
the noise is not significant on the gray
scale.
9-18. Level Depend Adjustment
Preparation
.
Complete the setting as shown below by using the setup
menu.
MENU : PAINT
PAGE : 07
*
DETAIL1
ITEM :
DETAIL
→
ON
ITEM :
LEVEL DEPEND
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot the gray scale chart to fill the entire screen of the
under-scanned picture frame.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
Adjustment point :
1
lens iris
Specifications :
A = 700
±
14 mV.
Adjustment Procedure
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
1.
Complete the adjustment as shown below by using the
setup menu.
MENU :
PAINT
PAGE :
07
*
DETAIL1
ITEM :
LEVEL DEPEND
Specifications : Decrease the details signal amplitude
of the portion B to the level that does
not affect the detail signal level at the
portion A.
Note
Upon completion of this adjustment, be sure to perform the
following two adjustments : “9-20. H/V Ratio Adjustment”
and “9-21. Detail Signal Level Adjustment”.
A
A
B
B
A
9-17. Crispening Adjustment