4-69
HDW-750/750CE V1
VF DETAIL Display (Setting the VF details)
Item
Setting
Function
VF DETAIL LEVEL
(
_
99 to 99)
Sets the amount of the VF detail signal.
(Amount of the detail signal of the main line video signal
remains unchanged.)
VF DTL H LEVEL
(
_
99 to 99)
Sets the amount of the VF H detail signal.
(Amount of the detail signal of the main line video signal
remains unchanged.)
VF DTL V LEVEL
(
_
99 to 99)
Sets the amount of the VF V detail signal.
(Amount of the detail signal of the main line video signal
remains unchanged.)
VF DTL WHT LIMIT
(
_
99 to 99)
Sets the white peak of the white limiter of the VF detail
signal.
(It does not affect the amount of the detail signal of the
main line video signal.)
VF DTL BLK LIMIT
(
_
99 to 99)
Sets the black peak of the black limiter of the VF detail
signal.
(It does not affect the amount of the detail signal of the
main line video signal.)
MEASURE Display (Setting the measurement mode)
Item
Setting
Function
MEASUREMENT MODE
OFF
/
S/N
/
MODU
/
RESO
/
Selects the measurement mode.
SENS
/
REGI
S/N :
S/N ratio measurement mode
MODU : Modulation measurement mode
RESO : Resolution measurement mode
SENS : Sensitivity measurement mode
REGI : Registration measurement mode
MASTER BLACK
(
_
99 to 99)
Adjusts the master black level. (All of the R, G and B
signal black levels are adjusted.)
MASTER GAIN (TMP)
_
3/0/3/6/9/12/18/24/30/
Sets the temporary gain value.
36/42
? 10
O
VF DETAIL
VF DETAIL LEVEL : 0
VF DTL H LEVEL : 0
VF DTL V LEVEL : 0
VF DTL WHT LIMIT: 0
VF DTL BLK LIMIT: 0
4-9. SERVICE Menu
? 11
O
MEASURE
MEASUREMENT MODE: OFF
MASTER BLACK : 0
MASTER GAIN(TMP): 0dB