9-11
HDW-750/750CE V1
9-9. Pre Knee Adjustment
Preparation
.
OUTPUT/DCC switch (inside panel)
→
CAM/OFF
.
WHITE BAL switch (inside panel)
→
PRST
.
Complete the setting as shown below by using the setup
menu.
MENU : PAINT
PAGE : 01
*
SW STATUS
ITEM :
GAMMA
→
OFF
ITEM :
TEST SAW
→
ANALOG
Adjustment Procedure
Equipment :
HD analog waveform monitor
Measurement point : TEST OUT connector (outside panel)
1.
Complete the setting as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
OUTPUT SELECT
→
R
ITEM :
PREKNEE ADJ MODE
→
ON
2.
Complete the adjustment as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
R PRE KNEE
Specifications : A = 700
±
5 mV
3.
Complete the setting as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
OUTPUT SELECT
→
G
4.
Complete the adjustment as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
G PRE KNEE
Specifications : B = 700
±
5 mV
5.
Complete the setting as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
OUTPUT SELECT
→
B
6.
Complete the adjustment as shown below by using the
setup menu.
MENU :
SERVICE
PAGE :
03
*
VA ADJUST
ITEM :
B PRE KNEE
Specifications C = 700
±
5 mV
Setting upon Completion of Adjustment
Complete the adjustment as shown below by using the
setup menu.
MENU : PAINT
PAGE : 01
*
SW STATUS
ITEM : GAMMA
→
ON
ITEM : TEST SAW
→
OFF
MENU : SERVICE
PAGE : 03
*
VA ADJUST
ITEM : PREKNEE ADJ MODE
→
OFF
A, B, C
9-9. Pre Knee Adjustment