5-18
HDW-750/750CE V1
5-8. Special Saving Items
5-8-1. White Gain
Using the REFERENCE file
Executing item
Status after execution
REFERENCE STORE ([REFERENCE] display)
The white gain values during execution are saved.
(When the WHITE BAL switch is in A, the value of A is
saved. When it is in B, the value of B is stored. When it is
in PRST, the value of PRST is stored.)
The white gain value that is assigned by the [PRESET
WHT] display with the WHITE BAL switch being set in
PRST, is saved.
REFERENCE CLEAR ([REFERENCE] display)
Both R/B GAIN values are set to 0 (3200K).
PRESET of the setup value ([PRESET WHT] display)
The value returns to the REFERENCE file value.
Using the SCENE file
.
When “SCENE WHITE DATA” is set to ON using the [REFERENCE] display
Executing item
Status after execution
SCENE STORE ([SCENE FILE] display)
The white gain values during execution are saved.
(When the WHITE BAL switch is in A, the value of A is
saved. When it is in B, the value of B is stored. When it is
in PRST, the value of PRST is stored.)
The white gain value that is assigned by the [PRESET
WHT] display with the WHITE BAL switch being set in
PRST, is saved.
SCENE RECALL ([SCENE FILE] display)
The white gain values during execution are replaced by
the SCENE file values. However, when “RECALL” is
executed with the WHITE BAL switch being in the PRST
position, the values are not replaced.
SCENE STANDARD ([SCENE FILE] display)
The white gain values during execution become the
REFERENCE file values.
.
When “SCENE WHITE DATA” is set to OFF using the [REFERENCE] display
Executing item
Status after execution
SCENE STORE ([SCENE FILE] display)
The white gain values during execution are saved.
SCENE RECALL ([SCENE FILE] display)
The white gain values are not rewritten.
SCENE STANDARD/CANCEL ([SCENE FILE] display)
The PRESET value and the white gain values during
execution are not replaced.