3-6
HDW-750/750CE V1
SLACK-62
Contents :
Time-over of the function cam reverse rotation is detected.
Detecting conditions : The function cam cannot complete its reverse rotation within the specified time.
Suspected cause :
.
Mechanical load to the gear block is so high that it cannot drive the function
cam. (Mechanical reason)
.
Reflection seal for detecting the cam position is dirty.
.
Loading motor is defective.
.
Loading motor drive circuit (MDC-13, SS-92 boards) is defective.
.
Cam position detector circuit (MDC-13, SS-92 boards) is defective.
SLACK-63
Contents :
Time-over of the tape top sensor is detected.
Detecting conditions : The short-forward tape movement after tape top detection cannot be completed
within the specified time.
Suspected cause :
.
Tape tension is so high that the tape cannot run. (Mechanical reason)
.
Tape position detector sensor circuit (MDC-13, SS-92 boards) is defective.
.
Tape top sensor is defective.
SLACK-64
Contents :
Time-over of the full top sensor is detected.
Detecting conditions : Tape full top is detected at the end of loading.
Suspected cause :
.
Tape position detector sensor circuit (MDC-13, SS-92 boards) is defective.
.
Full top sensor is defective.
SLACK-65
Contents :
Time-over of the tape end sensor is detected.
Detecting conditions : The short-reverse tape movement after tape end detection cannot be completed
within the specified time.
Suspected cause :
.
Tape tension is so high that the tape cannot run. (Mechanical reason)
.
Tape position detector sensor circuit (MDC-13, SS-92 boards) is defective.
.
Tape end sensor is defective.
SLACK-70
Contents :
Abnormality is detected in the servo EEPROM communication.
Detecting conditions : (1) The error in the communication with the servo EEPROM is detected.
(2) The checksum does not match.
Suspected cause :
.
IC403 on the MDC-13 board is defective.
.
Signal path between the MDC-13 board and the SS-92 board is defective.
SLACK-71
Contents :
Abnormality is detected in the system control initialization command.
Detecting conditions : The initialization command is not completed within the specified time at the event
of power-on with a cassette being inserted.
Suspected cause :
.
Signal path between the FP-121 board and the SS-92 board is defective.
3-1. When Does the Error Code Appear?