5-19
HDW-750/750CE V1
5-8-2. CC/ND Filter
The filter position of the CC and ND filters can be saved in the REFERENCE file and in the SCENE file.
When the motor-powered filter is attached optionally, the filter is electrically controlled to set the filter in
the specified position when the filter position data is read from the file.
When the motor-powered filter is not attached, the filter position data is read and saved as an information
but the filter is not controlled.
5-8-3. Master Gain
The Master Gain value can be saved in the REFERENCE file and in the SCENE file.
However, the Master Gain value is not controlled and the present value is maintained even though the
Master Gain value is read from the files.
(The Master Gain value is determined by the hardware switch.)
If the remote control devices that do not have the GAIN hardware switches such as MSU, the value is
changed to what is read from the file.
5-8-4. Shutter
The SHUTTER ON/OFF data, ECS frequency data and SHUTTER SEL value can be saved in the
REFERENCE file and in the SCENE file.
The ECS frequency data and SHUTTER SEL value are controlled by the setup data that are read from the
files, but the SHUTTER ON/OFF is determined by the hardware switch.
If the remote control devices that do not have the SHUTTER hardware switches such as MSU, the value
is changed to what is read from the file.
5-8. Special Saving Items