4-26
HDW-750/750CE V1
GAMMA Display (Adjusting gamma)
Item
Setting
Function
GAMMA
OFF/ON
Turns ON/OFF the gamma correction function.
MASTER GAMMA
(
_
99 to 99)
Adjusts the master gamma correction curve.
R GAMMA
(
_
99 to 99)
Adjusts the R gamma correction curve.
G GAMMA
(
_
99 to 99)
Adjusts the G gamma correction curve.
B GAMMA
(
_
99 to 99)
Adjusts the B gamma correction curve.
OUTPUT SELECT
Y/R/G/B/RGB
*
1
Selects the video signal that is output from the TEST
OUT and the VBS/SDI OUT terminal.
(The Y-signal becomes the VBS signal when the
REAR BNC OUT SEL of the OUTPUT SEL display of
the OPERATION menu selects the VBS position and
when the TEST OUT SELECT chooses the SD
position.) The output signal returns to the Y-signal
without fail at power-on.
GAMMA SELECT
STD/FILM
Selects the major classifications of gamma.
STD :
Standard
FILM : Film-like
n
Serial No.70000 and No.80000 series:
Selection of STD or FILM is possible.
Serial Nos. other than 70000 and 80000 series:
Fixed to STD when the AT version is before 1.40.
Selection is possible when the AT version is 1.40 and
higher.
GAM SEL (STD)/(FILM)
1 to 4
Selects the gamma curve.
(STD), (FILM) display is switched by selecting the
afore-mentioned GAMMA SELECT.
*
1 : RGB can be selected only when the Camcorder is used in the service mode.
? 04
O
GAMMA
GAMMA : ON
MASTER GAMMA : 0
R GAMMA : 0
G GAMMA : 0
B GAMMA : 0
OUTPUT SELECT : Y
GAMMA SELECT : STD
GAM SEL (STD) : 3