4-68
HDW-750/750CE V1
SD ADJUST Display (down converter out adjustment (Valid only when the down
converter board is installed))
Item
Setting
Function
SD SDI LOCK/FREE
LOCK/FREE
Sets the oscillator in a free-running state when FREE is
selected.
SD SDI VCO FREQ.
(
_
99 to 99)
Adjusts the free-running frequency of SD SDI.
SD VBS LEVEL
(
_
99 to 99)
Adjusts the VBS OUT signal level.
SD VF Y LEVEL
(
_
99 to 99)
Adjusts the Y-signal level that is output to SD VF.
SD VF R-Y LEVEL
(
_
99 to 99)
Adjusts the R-Y signal level that is output to SD COLOR VF.
SD VF B-Y LEVEL
(
_
99 to 99)
Adjusts the B-Y signal level that is output to SD COLOR VF.
SD VF CLAMP LVL
(
_
99 to 99)
Adjusts clamp level of the Y-signal that is output to SD VF.
VTR MODE-7 Display (Setting-7 on VTR)
Item
Setting
Function
FAN MODE
AUTO/FIX
Sets the fan mode.
Use the fan in the AUTO position normally.
AUTO : Temperature increase inside the unit is detected
and the fan is automatically controlled.
FIX :
The fan is controlled with the fixed voltage (8 V).
(For the operation check of the fan)
? 08
O
SD ADJUST
SD SDI LOCK/FREE: LOCK
SD SDI VCO FREQ.: 0
SD VBS LEVEL : 0
SD VF Y LEVEL : 0
SD VF R-Y LEVEL : 0
SD VF B-Y LEVEL : 0
SD VF CLAMP LVL : 0
? 09
O
VTR MODE-7
FAN MODE : AUTO
4-9. SERVICE Menu