2-2
BKS-R3219A/R1617A I&SSM
2-2. Operating Environment
Operating guaranteed temperature :
+
5
d
C to
+
40
d
C
Performance guaranteed temperature :
+
10
d
C to
+
35
d
C
Operating humidity :
10 % to 90 %
Storage temperature :
_
20
d
C to
+
60
d
C
Mass :
BKS-R3219A/R1617A :
Approx. 1.5 kg
To prevent overheating of the unit ensure that there is good
air circulation around the unit.
Select an installation place as operating temperature of the
unit is 5
d
C to 40
d
C. Do not place the unit near heart
sources.
2-3. Power Supply
1. Power Specifications
A switching regulator (
+
12 V) is used for the power
supply of this unit. A voltage within the range of AC 100
to 240 V can be used without changing the supply voltage.
Power requirements :
AC 100 to 240 V
Power frequency :
50/60 Hz
Current consumption :
BKS-R3219A/R1617A : 0.35 to 0.15 A
n
As the inrush current at turn-on is a maximum of 13 A (at
100 V) /47 A (at 240 V) with the BKS-R3219A, or a
maximum of 12 A (at 100 V) /40 A (at 240 V) with the
BKS-R1617A, the capacity of the AC power must be
commensurate with this source load.
If the capacity of the AC power is not adequately large, the
AC power source breaker will operate or the unit will
abnormally operate.
For customers in the U.S.A. and Canada
1
Power cord, 125 V 10 A (2.4 m) :
!
1-551-812-31
AC inlet
1
For customers in the all European countries
1
Power cord, 250 V 10 A (2.5 m) :
!
1-782-929-12
1
AC inlet
2. Recommended Power Cord
w
.
Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safety regulations of each country if
applicable.
.
Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
.
Never use an injured power cord.
.
Plugging the power cord in the AC inlet, push as far as it
will go.