![Sony BKS-R1617A Installation And Setup Manual Download Page 57](http://html.mh-extra.com/html/sony/bks-r1617a/bks-r1617a_installation-and-setup-manual_417506057.webp)
5-5
BKS-R3219A/R1617A I&SSM
5-1-3. Relationship With Z: SET PANEL
STATUS Setting Items
Route Change
Normal route function will issue the switch command to
the downstream Switcher 2 at the same time when the
switch command is issued for the upstream Switcher 1, but
this function will stop the issuing of the switch command
for downstream Switcher 2 when it is set to disable.
n
Refer to Section “3-4 Secondary Station Menu” “Z: SET
PANEL STATUS” ROUTE CHANGE Item for descrip-
tion on contents of setting.
5-1-4. Restrictions
1. Multistage Connection of Route Setting
Route setting is possible to set in multistage as following.
Route Dest
Dest
Src
Lv
Route1
OUTA
OUTB
INB
LVA
Route2
OUTB
OUTC
INC
LVB
Route3
OUTC
OUTD
IND
LVC
Route4
OUTD
OUTE
INE
LVD
Fig. 9 Route Multistage Setting
Up to 5 stages is possible for route setting as in figure.
Deployment of cross-point over 5 stages or displaying of
source going over 5 stages for status display will not be
done.
2. Invalidity of Sharing Route Trunk
Same route trunk cannot be used by multiple route settings
when the route setting is set.
Route Dest
Dest
Src
Lv
Route1
OUTA
OUTB
INB
Level
Route2
OUTA
OUTC
INB
Level
Fig. 10 Impossible Setting Sharing Same Route Trunk
It is possible to share the trunk by using the simplified
Destination Offset.
Refer to Section “5-1-2 Example of Using Route Function.”
INA
OUTA
INB
OUTB
OUTC
Level
INA
OUTA
OUTB
OUTC
OUTD
OUTE
INB
INC
IND
INE
LVA
LVB
LVC
LVD
LVE