5-9
BKS-R3219A/R1617A I&SSM
5-3-2. Configuring the Settings
Selecting signal monitoring mode
1.
Select “Y: SET DISPLAY MODES” from the secondary station menu.
2.
Move the cursor to “PANEL FUNCTION =” and enter 2 (VIRTUAL MONITOR). The signal
monitoring mode is set.
n
When the virtual monitor is selected (the [MON] button lights up green), the monitor function will
not be canceled even after pressing the [MON] button on the panel. Cancel the function with the “Y:
SET DISPLAY MODES” setting on the control terminal.
Setting the output terminal for the signal monitor
3.
Select “N:SET PANEL TABLE” from the secondary station menu.
4.
Move the cursor to “CONTROL DESTINATION =” and enter the number of the terminal that you
want to assign to the monitoring function.
5-3-3. Panel Display
The remote panel display becomes the following.
SONY ROUTING SYSTEM SETUP MENU BKS-R1617A V2.23 STATION NUMBER 2
SET PANEL TABLE(SOURCE) CONTROL DESTINATION = OUT002
01 KEY=IN001 02 KEY=IN002 03 KEY=IN003 04 KEY=IN004
05 KEY=IN005 06 KEY=IN006 07 KEY=IN007 08 KEY=IN008
09 KEY=....... 10 KEY=....... 11 KEY=....... 12 KEY=.......
13 KEY=....... 14 KEY=....... 15 KEY=....... 16 KEY=.......
SET PANEL TABLE(DESTINATION)
01 KEY=....... 02 KEY=....... 03 KEY=....... 04 KEY=.......
05 KEY=....... 06 KEY=....... 07 KEY=....... 08 KEY=.......
09 KEY=OUT001 10 KEY=OUT002 11 KEY=OUT003 12 KEY=OUT004
13 KEY=OUT005 14 KEY=OUT006 15 KEY=OUT007 16 KEY=OUT008
0=IN 1=OUT 2=SONY 3=VTR 4=SUP 5=CB 6=AIR 7=ME
8=PGM 9=CL A=SL B=L C=RET D=MIX E=JEEP F=OSC
G=L/A H=REM I=CAM J=STDO K=AUX L=COV M=BS N=CS
O=SAT P=CG Q=WETH R=TEST S=HD T=D1- U=D2- V=SEG
Ctrl-E:MENU Ctrl-D:RETURN Ctrl-N:DESCRIP.NAME T:TAKE M:MONI V:VTR E:LEVEL
Ex.: Output the result from monitoring
on the OUT002 terminal.
Note for the signal monitoring mode
In this mode, the setting for “SOURCE OFFSET:” of “Z: SET PANEL STATUS” in the secondary
station menu is valid.
This setting is reflected when monitoring the destination.
BKS-R1617A
MONI
“ MONI ” is displayed