2-9
BKS-R3219A/R1617A I&SSM
2-11-2. Setup Operations
With the S-BUS system, the necessary items are normally
set at the control terminal connected to the primary station.
However, the following items may be set on the unit by
turning the power on while holding down the two or more
select buttons, as described below.
Initializing the settings
While holding down buttons 1 and 2, turn the power on.
The following items are set to the factory-set conditions.
1) Status display mode
2) Single-use mode
3) Phantom partial-protect mode
n
Press buttons until the lamp check on the panel is completed.
Setting single-use mode
While holding down buttons 5 and 8, turn the power on.
Use this mode when this unit is to be used alone.
Setting prompt lamp-light mode
While holding down buttons 1 and 3, turn the power on.
When you press a source select button, the lamp of the
pressed button promptly lights.
Setting status display mode
While holding down buttons 1, 2 and 3, turn the power on.
When you press a source select button, the system checks
that the designated crosspoint has been switched, then the
button lights according to the crosspoint status.
Setting 32-source select mode (BKS-R3219A)
While holding down buttons 1 and 4, turn the power on.
All the source/destination select buttons work as source
select buttons.
Setting 16-source select mode (BKS-R1617A)
While holding down buttons 1 and 4 (or 5 and 7), turn the
power on.
All the source/destination select buttons work as source
select buttons. For selecting a destination, press the DEST
button to make it lit, then turn the SELECTOR knob.
Setting 16-source/16-destination select mode 1
(BKS-R3219A)
While holding down buttons 5 and 6, turn the power on.
Select buttons 1 through 8 and 17 through 24 function as
source select buttons, and select buttons 9 through 16 and
25 through 32 function as destination select buttons.
Setting 16-source/16-destination select mode 2
(BKS-R3219A)
While holding down buttons 5 and 7, turn the power on.
Select buttons 1 through 16 function as source select
buttons, and select buttons 17 through 32 function as
destination select buttons.
Setting 8-source/8-destination select mode
(BKS-R1617A)
While holding down buttons 5 and 6, turn the power on.
Select buttons 1 through 8 function as source select
buttons, and select buttons 9 through 16 function as
destination select buttons.
Setting phantom full-protect mode
While holding down buttons 9 and 11, turn the power on. If
one of the crosspoints set for a phantom is protected,
switching of all the crosspoints of the phantom is prohibited.
Setting phantom partial-protect mode
While holding down buttons 9, 10 and 11, turn the power on.
If one of the destinations set on a phantom is protected,
switching of the crosspoints, including the protected destina-
tion, is prohibited, but the other crosspoints are switched.
Entering station number setting mode
While holding down buttons 1, 2, 3 and 4, turn the power on.
The station number can be set with binary coding using
buttons 1 through 8.
Resetting the software
Press and hold the LOCK and PROT buttons for five
seconds. Then the software is reset, and the same status as
the power is turned on is obtained.
9
10 11 12
25 26 27 28
13 14 15 16
29 30 31 32
1
2
3
4
17 18 19 20
5
6
7
8
21 22 23 24
1
2
3
4
9
10 11 12
5
6
7
8
13 14 15 16
BKS-R3219A
BKS-R1617A
Number of the source/destination select buttons