4-2
BKS-R3219A/R1617A I&SSM
4-2-1. Function Check after Power On
When the power of the primary station is turned on, results of the self-diagnosis of the primary station and
the ROM checksum value will be displayed as shown below.
For details, refer to the System Setup Manual corresponding to each unit of the primary station.
Example of the primary station system status screen after power on (HKSP-R80)
4-2-2. Function Check with Menu Item [V : DISPLAY UNIT STATUS]
The internal settings can be checked if they contain an error or not, using the secondary station menu [V:
DISPLAY UNIT STATUS].
4-2-3. Function Check with Menu Item [W : SYSTEM STATUS LOG]
When you want to check details of the log content and time of error occurrence, select the menu item [W:
SYSTEM STATUS LOG]. The log information that is stored in the memory of the primary station can be
displayed.
4-2-4. System Status Log
When a message is output to the S-BUS data link, the system status screen will display the message with
the date and time of occurrence. When any change takes place during the operation of the system, the
error message will be displayed.
Example of system status screen during system operation
See the Installation Manuals and System Setup Manuals of each primary stations for the description of the
message displayed in the system status log, which is displayed on the personal computer.
SONY ROUTING SYSTEM SETUP MENU
HKSP-R80 V1.12
STATION NUMBER 1
ITEM
ROM CHECK SUM 38CD
RAM READ AND WRITE OK
REFERENCE SIGNAL OK
S-BUS LINK TERMINATE
REAL TIME CLOCK OK
STARTED
Ctrl-X to SYSTEM SETUP MENU
2007.05.22-13.15 S-BUS LINK DISCONNECTED TO CHANNEL A
2007.05.22-13.15 S-BUS LINK DISCONNECTED TO CHANNEL B2
2007.04.12-15:42 S-BUS LINK DISCONNECTED TO CHANNEL A
2007.04.12-16:28 STARTED BY BKS-R3219A Ver2.23 IN STATION 11
2007.04.12-17:31 STARTED BY BKS-R1617A Ver2.23 IN STATION 32
2007.04.12-18:51 MISSING REFERENCE SIGNAL IN STATION 10
2007.04.12-19:15 POWER SUPPLY UNIT B DOWN IN STATION 4
2007.04.12-20:11 X-POINT ERROR IN STATION 10
2007.04.12-21:45 STARTED BY BKS-R6010 Ver1.00 IN STATION 25
Error message