6-42
FVS-1000 MMP1
5.
Place the mirror adjusting tool on the gate base
assembly as shown in the figure.
6.
Select the mode number 18 from the control panel, and
set the IRIS data to around “5600”.
7.
Adjust the screen is turned black and white using ND
filter (mode number 19) and lamp control (mode
number 02).
8.
Adjust the camera position (mode number 08 and 18)
so that the square chart of the resolution chart is shot
to the full screen of the monitor.
Mirror adjusting tool
Gate base (35)assembly
Chart holding tool
Resolution chart
9.
When adjusting the horizontal direction on the monitor
screen, loosen the adjusting screw and rotates the
anamo block of the lens shown in the figure so that the
square chart turns rectangle.
.
When the top of the rectangle is leaned to the right
(Fig. 1):
Rotate the ring to A direction.
.
When the top of the rectangle is leaned to the left
(Fig. 2):
Rotate the ring to B direction.
10. Tighten the adjusting screw loosened in step 9.
11. Tighten the three setscrews loosened in step 2 using L-
shaped wrench (1 mm).
12. Apply the locking compound to the three setscrews
removed in step 1, and tighten these screws to the lens
using L-shaped wrench (1.5 mm).
13. Check the generating line is not slanting using the
resolution chart again.
6-11. BKFV-410
Aspect conversion lens
Master zoom lens
Adjusting screw
A
B
(Fig. 1)
(Fig. 2)