3-10
FVS-1000 MMP1
3-3-3. Cleaning the FLC Assembly
1.
Remove the gate base (35) assembly.
(Refer to Section 3-2-1.)
2.
Remove the integrater assembly from the gate base
(35) assembly.
3.
Loosen the four screws (with stopper), and pull out the
lamp house assembly. (Refer to Section 3-4-1.)
4.
Loosen the three screws (with stopper), and remove
the lamp house cover. (Refer to Section 3-4-1.)
Integrater assembly
(1) Blow off the dusts on the glass surface (2 locations) of
the integrater assembly using the air blower for optical
use.
(2) For stubborn dusts which cannot be removed using the
air blower, clean with a cleaning cloth moistened with
cleaning liquid for optical use.
n
After cleaning, install the integrater assembly after the
cleaning liquid has evaporated completely.
F-FLC
n
Do not push the glass side of the F-FLC with force or hit it
with a hard object as this may cause the performance of the
FLC assembly to drop considerably, or disable use.
(1) Blow off the dusts on the glass side of the F-FLC
using the air blower for optical use.
(2) For stubborn dusts which cannot be removed using the
air blower, clean with a cleaning cloth moistened with
cleaning liquid for optical use.
n
After cleaning, install the lamp house assembly after
the cleaning liquid has evaporated completely.
F-FLC
Lamp house assembly
3-3. Cleaning the Optical System
Gate base (35) assembly
Glass
Glass
Integrater assembly