![Sony BKFV-100/1 Maintenance Manual Download Page 196](http://html.mh-extra.com/html/sony/bkfv-100-1/bkfv-100-1_maintenance-manual_417896196.webp)
5-2
FVS-1000 MMP1
5-1-2. Checking the Film Control Motor
The operation checks of the following DC motor and sensor are performed by inputting commands.
Checking procedure
1.
Connect the PC to this unit (CN101/SV-191 board) with the PC connection cable (9 pin-ELCO).
2.
Turn on the power of this unit.
3.
Start the HyperTerminal (terminal emulation software) and input “FILM.”
“TEST MODE” will be displayed and the test mode of servo system is set.
4.
Input the following commands and check the operation of the motor.
Block
Command
Function
S tension arm
S REG CLOSE
S tension arm moves to threading position
*
S REG OPEN
S tension arm moves to unthreading position
*
T tension arm
T REG CLOSE
T tension arm moves to threading position
*
T REG OPEN
T tension arm moves to unthreading position
*
S PT roller
S PT CLOSE
S PT roller moves to threading position
*
S PT OPEN
S PT roller moves to unthreading position
*
T PT roller
T PT CLOSE
T PT roller moves to threading position
*
T PT OPEN
T PT roller moves to unthreading position
*
S pad
S PAD CLOSE
S pad moves to threading position
*
S PAD OPEN
S pad moves to unthreading position
*
T pad
T PAD CLOSE
T pad moves to threading position
*
T PAD OPEN
T pad moves to unthreading position
*
Gate (retainer assembly)
GATE MID
Retainer assembly moves to the middle position
*
GATE CLOSE
Retainer assembly closes
*
GATE OPEN
Retainer assembly opens
*
S brake
S BRAKE OFF
Releases the brake of the S reel assembly
S BRAKE ON
Applies the brake of the S reel assembly
T brake
T BRAKE OFF
Releases the brake of the T reel assembly
T BRAKE ON
Applies the brake of the T reel assembly
*
: When the sensor detects the completion of operation, “OK” will be displayed on the PC screen.
5.
To exit the test mode, input “NORMAL.”
5-1. Test Mode for Servo System Check