4-3
FVS-1000 MMP1
35/16T Pad Assembly
Removal
1. Removing the pad assembly
Rotate the two rings of the 35/16T pad assembly
with your fingers in the counterclockwise direc-
tion, and remove the 35/16T pad assembly.
Installation
2. Installing the pad assembly
(1) Align the reference hole and long hole of the
35/16T pad assembly and the pad positioning
shaft.
n
At this time, check that the pad drive pin
enters the pad arm holes.
(2) Press the 35/16T pad assembly against the
base plate, rotate the two rings with your
fingers in the clockwise direction, and install.
4-2. Replacing the Pad Assembly
Pad driving pins
35/16 T Pad assembly
Pad positioning shaft
Pad positioning shaft
Ring
Ring
Hole of Pad arm