6-27
FVS-1000 MMP1
6-7. Processor Adjustment (Including
BKFV-200)
6-7-1. ADC-36 Board Adjustment
Measuring instrument: Waveform monitor
Tool:
Extension board EX-632
(For front)
Preparations
1.
Pull out the ADC-36 board using the extension board
EX-632 (for front).
2.
Set the mode as follows at the menu of the control
panel. (Refer to menu setting in the instruction manu-
al.)
Mode No.
Setting
*
F0
35
*
F1
POSI
*
F2
24/1. 001
*
F3
1125 . 30
*
F4
1
60I
*
F4
3
525 60I
*
F5
3
S
*
02
80.
80.
80.
80.
*
08
F5.
00.
AF.
FF.
*
10
00.
00.
00.
00.
*
11
00.
00.
00.
00.
*
11.
00.
00.
00.
00.
*
1. 1
00.
00.
00.
00.
*
1. 1.
00.
00.
00.
00.
*
12
00.
00.
00.
00.
*
12.
00.
00.
00.
00.
*
1. 2
00.
00.
00.
00.
*
1. 2.
00.
00.
00.
00.
*
14
_
0.
A0.
A0.
A0
*
15
00.
00.
00.
00.
*
18
56.
47.
59.
- -
*
19
_
0.
_
1.
- -
- -
*
22
- -.
_
7.
_
7.
_
7
*
26
- -.
00.
00.
00.
*
23
FF
FF
*
32
80
80
3.
Select the SD system OUT 3 at the control panel, and
set as follows.
Mode No.
Setting
*
42
0000 7FFF 4A00 0A00
*
42.
40
80
60
40
*
43
ALL 0
*
44
ALL 0
*
46
FF
*
47
0400 7FFF 4A00 0A00
*
47.
0020 0100 0080 0040
*
60
ALL 0
*
61
ALL 0
4.
Set the menu of the control panel, and turn ON the
INT SG of the imager.
Menu setting: MENU
→
COLOR
→
TEST
→
SG ON
Adjustment
1.
Connect the waveform monitor to D-1 SDI 1 of the SD
OUT board of the connector panel.
2.
Adjust so that the waveform satisfies the specification.
Adjustment RV
Name
RV401/ADC-36 (P-3)
G-ch BLACK LEVEL
RV701/ADC-36 (P-5)
B-ch BLACK LEVEL
RV101/ADC-36 (P-9)
R-ch BLACK LEVEL
RV402/ADC-36 (P-3)
G-ch WHITE LEVEL
RV702/ADC-36 (P-5)
B-ch WHITE LEVEL
RV102/ADC-36 (P-9)
R-ch WHITE LEVEL
Specification:
A = 700
±
7 mV dc
B =
+
7
mV dc
_
0
6-7. Processor Adjustment (Including BKFV-200)
B
GND
A
ADC-36 board (A side)
RV402
RV401
RV702
RV701
RV102
RV101
1
2
3
4
5
6
7
8
9
K
L
M
N
P