5-3
FVS-1000 MMP1
Imager movement table
assembly
G
F
B
D
C
A
E
5-1-3. Checking the Imager Movement Table Assembly Control Motor
The operation checks of the stepping motor controlling the imager movement table assembly are per-
formed by inputting commands.
Checking procedure
1.
Connect the PC to this unit (CN101/SV-191 board) with the PC connection cable (9 pin-ELCO).
2.
Turn on the power of this unit.
Initial setting of the imager movement table assembly starts and stops at the specified position after
turning on the power.
3.
Start the HyperTerminal (terminal emulation software) and input “FILM.”
“TEST MODE” will be displayed and the test mode of servo system is set.
4.
Sequentially after inputting the following command, input “00000000” and the following position
data to check the operation of the motor.
Block
Command
Position data
Function
X axis
CAM X
00001000
Imager movement table assembly moves to arrow A direction
CAM X
FFFFE000
Imager movement table assembly moves to arrow B direction
Y axis
CAM Y
00001000
Imager movement table assembly moves to arrow C direction
CAM Y
FFFFE000
Imager movement table assembly moves to arrow D direction
Z axis
CAM Z
FFFFE000
Imager movement table assembly moves to arrow E direction
Theta axis
CAM T
00001000
Imager movement table assembly rotates to arrow F direction
CAM T
FFFFE000
Imager movement table assembly rotates to arrow G direction
5.
To exit the test mode, input “NORMAL.”
5-1. Test Mode for Servo System Check