6-19
FVS-1000 MMP1
Adjustment
Light amount adjustment
Note: In the following,[ENTER] means the ENTER key.
1.
Turn ON the power. (Lamp turns ON)
2.
Wait for the hyper terminal window to display
“READY”.
3.
Wait 10 minutes or more to stabilize after the light is
turned ON.
4.
Turn the light source of integrating sphere blinking to
bright.
Select “flc” on the PC and press [ENTER].
After 30 seconds, the light returns blinking. At this
time, select “flc” on the PC again.
5.
Insert the head block of the illumination photometer to
the aperture of the gate base (35) assembly, and put it
on the grass of the integrating sphere.
In this condition, adjust the location of the head so that
the measurement value of the illumination photometer
is maximum.
6.
Adjust the RV
*
of the LC-35 board so that the value of
the illumination photometer satisfies the specification.
*
: LC-35 board No. suffix -13 and higher: RV701
LC-35 board No. suffix -12:
RV400
Specification: 40000 Lx
LC-35 board (Suffix -12, Side A)
RV401
RV400
E101
TP400
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
J
K
LC-35 board (Suffix -13 and higher, Side A)
5
4
3
2
1
B
A
C
D
E
F
RV401
CN15
RV431
RV461
E2
RV701
RV702
TP305
TP704
TP303 TP301
6-6. Lamp House Adjustment
Gate base (35) assembly
Integrating sphere
Glass face
Head of illumination photometer