The
Source Spigot
screen items are described in Table 23, Table 24, Table 25, and Table 26.
Setting
Description
Spigot Selection
Drop down box.
Select which multiviewer source spigot to show.
•
MV-805-16
: Select Spigot 1 to Spigot 4.
•
MV-805-32
: Select Spigot 1 to Spigot 8.
(Source spigots are the MV-805 video outputs.)
Table 23
Source Spigot Selection
Extended Header
Setting
Description
Disable Extended Headers
Check box.
Tick to disable extended RTP headers in the sourced IP flow.
(For example, this may be required for TR-03/04 compatibility.)
Packet Time
Drop down box.
Select the length of time represented by the media in each IP flow packet.
In ‘Auto’ mode, the
Packet Time
is determined by the number of audio channels.
If the number of audio channels is 32 or less,
Packet Time
is typically set to 250 us.
Num Audio Chans
Drop down box.
Select the number of audio channels in the IP flow packets.
In ‘Auto’ mode, the number of audio channels is determined by the number of audio channels
assigned (in the edge device configuration) to the output IP stream.
Note:
The MV-805 does not currently support audio on its display outputs. Set this to ‘Auto’.
Table 24 Extended Headers Information (Source Spigot Screen Item)