5.3 Preparing the Unit and the Rack
5.3.1 Location in Rack
The MV-805 is designed to be installed in a standard 483mm (19 inch) equipment rack for
use. The unit requires a 1RU high space within a rack (see Section A.2 “Physical” on
page 129 for the unit’s depth dimensions).
The following precautions should be observed:
1.
Do not obstruct the front of the chassis: The whole front is a cooling air intake for the
chassis.
2.
Do not obstruct the rear of the chassis: Air exhausts out of the whole rear.
3.
Ensure that there is a minimum clearance at the rear of the mainframe of 200mm (8
inches). This is
ESSENTIAL
.
Caution:
Do not obstruct the chassis front.
Do not obstruct the chassis rear.
Caution: