MV-805 IP Multiviewer User Manual
Multiviewer Display Output
Getting Started 2 - IP Routing (Orbit) 8.6
Issue1 Revision 1
Page 105
© 2018 SAM
8.6.4 Default Multiviewer Video Wall with Video on Video Tiles
Figure 85 shows an example of a default video wall showing some video inputs on-screen.
8.6.5 Orbit IP Multiviewer Projects
The multiviewer project on the MV-805 unit can be read from the unit (“pulled”), edited and put
back onto the unit (“pushed”) with SAM Orbit. If the default project is pulled from the
multiviewer, it is recommended that the project is re-named in SAM Orbit before being pushed
back to the unit. Also, a new IP multiviewer project can be created with SAM Orbit.
(See the SAM Orbit for Multiviewers User Manual for instructions on using SAM Orbit for
Multiviewers.)
Figure 85 Default Multiviewer Video Wall with Video Inputs
Audio Bars
Video in Video Tiles
On-screen video standard
Note:
Restoring the default SAM Orbit IP multiviewer project:
The default multiviewer layout can be restored to a MV-805 unit by clicking the
Restore
Project
button in the unit’s RollCall
Reset
template. The current multiviewer layout will be
overwritten.
Note:
SAM Orbit Projects:
The SAM Orbit project home screen shows the ‘Project Name’, which
is treated as an
identifier by SAM Orbit. The name may be changed with the ‘Edit Name’ control in the
home screen.
Projects with the same name are considered to be the same and SAM Orbit warns the user
if there are any differences between a project in SAM Orbit and the same-named project on
a multiviewer device. Such differences must be resolved.
It is recommended to:
•
Use a different and unique project name for each multiviewer.
•
Rename a default project that has been pulled from a multiviewer.