MV-805 IP Multiviewer User Manual
System-Setup Template
RollCall Templates 6.2
Issue1 Revision 1
Page 60
© 2018 SAM
Setting
Description
RollCall IP Address
Text box.
Enter the static IP address of the network interface of the IP-RSC Router Controller
device that is connected to control panels etc.
Click the
S
button, to locally save a new setting.
Note:
Alternatively, if the TSL protocol is being used to get signal names, leave this
text box blank.
RollCall IP Port
Text box.
Enter the IP port number for the Router Controller device comms.
Click the
S
button, to locally save a new setting.
Multiviewer Destination Port Offset
Text box.
Enter the offset into the video router’s destination port range which the multiviewer’s
input spigots use.
The multiviewer obtains a full list of video router port names from the IP-RSC router
controller device. The
Multiviewer Destination Port Offset
is used by the multiviewer
as an offset into its full list of (destination) port names. The multiviewer can then
determine the names of the signals routed to its inputs (destination spigots).
The video router destination ports used by the multiviewer input spigots must be in
one contiguous range.
Click the
S
button, to locally save a new setting.
Table 14 Router Controller Settings
Note:
“S” and “P” buttons - After entering information in each text box, always click on the
adjacent “S” button or press “return” to locally save the new setting. Do this for each text
box. (Note: Clicking on the “P” button will return the setting to its preset default value).
“S” - Locally save new setting value (or press “return”).
“P” - Locally save default setting value.