MV-805 IP Multiviewer User Manual
System-Setup Template
RollCall Templates 6.2
Issue1 Revision 1
Page 55
© 2018 SAM
Domain ID
Text box.
Enter the R
Domain ID
number; click the
S
button to
locally
save the new setting.
(A R domain is used to segregate messages on a RollCall network.
There can be more than one domain on a network.)
Multiviewer Control Message Domain ID:
This R
Domain ID
is for multiviewer control messages:
•
The
Domain ID
can typically be left at its default value, 100.
(This default value is reserved for multiviewer R traffic.
To reset the
Domain ID
back to the default value of 100 click on the
P
button.)
•
SAM Orbit must use the same
Domain ID
when connecting to the MV-805 unit for
SAM Orbit Multiviewer projects.
See
Note 3
and
Note 4
.
Ethernet Interface
Drop down box.
Set which MV-805 physical network interface to use for R control messages etc.
Each of the physical network interfaces of the MV-805 system are shown in the drop-down
menu.
Select the IP address of the “Control” interface.
Note:
MV-805 only supports ‘out-of-band’ control.
Note 1: RollCall address:
The form of a RollCall address is:
NNNN:UU:PP
where:
NNNN is the RollCall Network ID number.
UU is the RollCall unit number.
PP is the multiviewer input number (01, 02 etc).
Note 2:
The
combination
of
RollCall Network
and
RollCall Unit
number must be unique in a
RollCall system.
Note 3: R Domains:
R uses the concept of domains to segregate messages on
a RollCall network. There can be more than one R Domain on a network.
Only RollCall-enabled devices on the same R Domain can communicate with each
other.
Note 4: R Domain IDs:
For the
MV-805
, there are two R domains required:
•
Multiviewer control messages domain.
•
IP routing messages domain.
Setting
Description
Table 12 RollCall Settings (Continued)