12. Enter a R
Domain ID
number. (This is the ‘IP Routing’ R domain.)
Use a R Domain ID that is different to the Domain ID in the RollCall Settings
section above.
13. Select an
Output Format
for the multiviewer display output as required.
7.2.6 Getting the Multiviewer Input Signal Names
This is done in the
Router Controller Settings
section of the System-Setup template (see
14. If the names for video signals going to the multiviewer are to be obtained from a TSL
server, from some other source, or they are not (yet) required,
then enter a blank for
RollCall IP Address
etc.
However,
if names for video signals going to the multiviewer are to be obtained from a Router Controller
device (via the SAM SW-P-08 protocol) then:
15. For
RollCall IP Address
,
enter the static IP address of the Router Controller (IP-RSC) network interface that is
used by control panels.
16. For
Multiviewer Destination Port Offset
,
enter the offset into the video IP router’s destination port range which is to be the
beginning of the router port range used by the multiviewer inputs.
Note:
If the offset is not yet known, set it to ‘0’ here and configure later, when known.
Note:
Network Interface Names:
Each network interface may have been re-named in the Network Settings section above.
Drop-down menu item names that appears in each drop-down menu are formed from the
interface name and its IP address: “Name : IP address”.
For example, “Fabric-A : 10.100.210.30”, and “Fabric-B : 10.100.220.30”.
Note:
‘IP Routing’ Domain ID:
The Domain ID used in the IP Fabric section of the System-Setup template is for IP
Routing R messages.
This should be the same as that used for:
•
A Router Controller or SAM IQTIC card connected to the MV-805 unit.
•
SAM Orbit connecting to the MV-805 unit for an IP Routing project.
Figure 60 Router Controller Settings Box
Note:
Multiviewer Destination Port Offset:
This can be determined with SAM Orbit for IP Routing.
The value of the
Multiviewer Destination Port Offset
setting can be set up later.
(See Section 8.3 “Find which Video Router Source and Destination Ports to Use” on page
95.)