MV-805 IP Multiviewer User Manual
Rack Mounting
Hardware Installation 5.4
Issue1 Revision 1
Page 41
© 2018 SAM
5.4 Rack Mounting
5.4.1 Mounting the MV-805 into a Rack
The MV-805 is shipped with two sets of rack rail assemblies and mounting brackets with
screws.
Preliminaries:
1.
Check that the rack is rigid enough for the unit chassis.
Rail-mounting:
2.
Refer to the chassis User Manual for details about any mounting rails.
(See Section A.1 “COTS Hardware Platform for the Turnkey MV-805” on page 129 in
this User Manual for
chassis manufacturer and model number information.)
3.
Position the unit in its rack-rails and secure it to the rails.
Use the correct lifting procedures.
4.
Secure the MV-805 chassis in the rack at each mounting hole using 2-off M6 rack
mount screws. See Figure 21.
Shelf-mounting:
5.
Use a suitable rack tray in the rack to take the weight of the MV-805 IP Multiviewer
.
The chassis rear will become heavier when cables are connected.
6.
Position the unit in the rack on a shelf or on its rack-rails.
Use the correct lifting procedures.
7.
Secure the MV-805 chassis in the rack at each mounting hole using 2-off M6 rack
mount screws. See Figure 21.
Warning:
The
MV-805 is heavy, approximately 27kg (~60lb), see Section A.2 Physical,
and it will require two people to lift into position, using correct lifting procedures.
If you are unsure of the lifting procedures, ask a Health and Safety adviser for information.
Note:
Please refer to the third-party-manufacturer information for full installation instructions of
the rack rails and the MV-805 chassis in a rack.
Note:
The chassis rear will become heavier when cables are connected