Rack Mounting
Hardware Installation 5.4
Issue1 Revision 1
Page 42
© 2018 SAM
5.4.2 Connecting Up in a Rack
When connecting cables to the MV-805 IP Multiviewer, it is recommended that cable supports
are used (clamps and bars) to relieve the strain on rear connectors.
Connections include:
•
2-off AC Power.
•
1-off 1Gbit ethernet to the “Control” network interface.
•
(Optional) 1-off 1Gbit ethernet to the “Control 2” network interface,
for a second control/service network connection.
•
Media network interface connections:
•
MV-805-32:
Up to 4-off 100Gbit ethernet connections to QSFP+ cages.
(2-off 100Gbit if
non-
redundant media IP fabrics).
•
MV-805-16:
Up to 2-off 100Gbit ethernet connections to QSFP+ cages.
(1-off 100Gbit if
non-
redundant media IP fabrics).
5.4.2.1
Media Network Connections
A MV-805 unit does not ship with QSFP28 modules fitted into the rear QSFP+ cages.
QSFP28 modules/cables must be bought separately to suit the unit’s system installation.
1.
Fit any QSFP28 modules/cables into the QSFP+ cages on the rear of the unit.
2.
Fit QSFP EMI/dust covers to any rear QSFP+ cages that are not connected.
Figure 21 MV-805 Rack Mounting
M6 Rack mounting screws
Chassis rails