System Management Commands
4-49
4
Syntax
show log
{
flash
|
ram
}
-
flash
- Event history stored in flash memory (i.e., permanent memory).
-
ram
- Event history stored in temporary RAM (i.e., memory flushed on
power reset).
Default Setting
None
Command Mode
Privileged Exec
Example
The following example shows the event message stored in RAM.
SMTP Alert Commands
These commands configure SMTP event handling, and forwarding of alert
messages to the specified SMTP servers and email recipients.
logging sendmail host
This command specifies SMTP servers that will be sent alert messages. Use the
no
form to remove an SMTP server.
Syntax
[
no
]
logging sendmail host
ip_address
Console#show log ram
[1] 00:01:30 2001-01-01
"VLAN 1 link-up notification."
level: 6, module: 5, function: 1, and event no.: 1
[0] 00:01:30 2001-01-01
"Unit 1, Port 1 link-up notification."
level: 6, module: 5, function: 1, and event no.: 1
Console#
Table 4-21. SMTP Alert Commands
Command
Function
Mode
Page
logging sendmail host
Specifies SMTP servers that will be sent alert messages GC
4-49
logging sendmail level
Sets the
severity threshold used to trigger alert
messages
GC
4-50
logging sendmail
source-email
Sets the
email address used for “From” field of alert
messages
GC
4-51
logging sendmail
destination-email
Specifies the email recipients of alert messages
GC
4-51
logging sendmail
Enables SMTP event handling
GC
4-52
show logging sendmail
Displays SMTP event handler settings
NE, PE
4-52
Summary of Contents for 8124PL2
Page 1: ...MANAGEMENT GUIDE TigerSwitchTM 10 100 1000 24 Port Managed Switch with PoE SMC8124PL2 ...
Page 2: ......
Page 20: ...xvi Contents ...
Page 27: ...xxiii Figures ...
Page 35: ...Introduction 1 8 1 ...
Page 45: ...Initial Configuration 2 10 2 ...
Page 148: ...Port Configuration 3 103 Figure 3 61 Displaying Etherlike and RMON Statistics ...
Page 473: ...Command Line Interface 4 240 4 ...
Page 477: ...Software Specifications A 4 A ...
Page 489: ...Index Index 4 menu list 3 3 panel display 3 3 ...
Page 490: ......