Ethernet communication
7.6 HT 8
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
209
Examples
Call of FC 26 for the first MCP, for the first mode group and the first channel of the NC.
BAGNo
:= B#16#01
// 1. MCP, 1st mode group of the NC
ChanNo
:= B#16#01
// 1. Channel of NC
Call of FC 26 for the second MCP, for the second data group and the third channel of the NC.
BAGNo
:= B#16#12
// 2. MCP, 2nd mode group of the NC
ChanNo
:= B#16#03
// 3. Channel of NC