Drive Optimization with HMI Advanced
14.3 Special functions
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
511
Traversing of the axis to be measured is enabled in addition to the interface signals
typical for JOG mode depending on the interface signal: "Drive test traversing enable".
7RJJOHNH\
Traversing range monitoring
The measuring functions have their own traversing range monitoring. With this monitoring
function the traverse range of an axis can be limited or monitored without having to reference
this axis.
The basis is the absolute axis position displayed in the "Status" group at the time of
measurement.
Activating
The traversing range monitoring is activated from the main menu of the appropriate
measuring function in the group "Traversing range". Refer to figure in Section "Special
Functions".
Choose the traversing range monitoring from the selection list "Monitoring" via the Toggle
key or by clicking with the right-hand mouse button on the required monitoring type:
●
Inactive
The axis is traversed without monitoring the traversing range.
●
Active
The axis is traversed with monitoring of the traversing range, depending on the traversing
range limits set:
●
High limit
●
Lower limit