Power-On and Power-Up
5.4 Service Desktop
Manual
136
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
5.4.2
SINUMERIK-specific applications
The following SINUMERIK-specific applications are available on the Service Desktop:
●
Ghost Explorer
The Ghost Explorer is used to display the content of Ghost images.
References:
The Ghost tools documentation is located on the PCU hard drive under: E:\TOOLS
●
HMI Explorer
The HMI Explorer is used to display the version and install or post-install the supplied
SINUMERIK application. See Section "HMI Explorer" (Page 140).
●
Touchware
Program for calibrating the touchscreen connected to the PCU directly.
References:
Equipment Manual "Operator components and Networking",
Chapter: PCU 50.3 > Commissioning > Calibration of the touchscreen
●
System Network Center
Setting up the Ethernet connection of a TCU to the SINUMERIK 840Di sl.
References:
Equipment Manual "Operator components and Networking",
Chapter: Networking > Commission system network > PCU: System Network Center
(SNC)
●
HMI Analyzer
Analysis tool for HMI Advanced in conjunction with PCU 50.3
References:
"Base software and HMI-Advanced" Commissioning Manual
Chapter: Diagnosis and Service > HMI-Analyzer
●
ServiceCenter
Starts the ServiceCenter after the computer reboots under WinPE to create, restore and
manage partition and hard disk images.
References:
"Base software and HMI-Advanced" Commissioning Manual
Chapter: PCU-Basesoftware 8.x > Save and restore data