Ethernet communication
7.5 MCP 483C IE
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
193
References:
/BHsl/ Operator Components Manual, Chapter "Machine Control Panel MCP 483C IE"
Display of the software version
After the MCP has been electrically connected, all LEDs on the front side of the MCP flash
until communication is established between MCP and PLC.
To activate the display you must press the "Feed stop" and "Feed enable" keys
simultaneously. The Version No. of the current software version is then displayed with the
help of the continuously illuminated LEDs.
Example: Software version: V 01.02.00
1. Digit
1)
2. Digit
1)
3. Digit
1)
Pressing the keys "Feed enable" and "Feed stop"
simultaneously
1
2
0
1) Display of the digit by means of continuously illuminated LEDs on the individual LED blocks
according to the following figure
'LJLW
OHIW/('EORFN
'LJLW
PLGGOH/('EORFN
'LJLW
ULJKW/('EORFN
$FWLYDWHGLVSOD\
Figure 7-5
Display of software version: 1 . 2 . 0